USB powered
Temperature control range
Temperature
control accuracy
NTC Temperature
measurement range
Yes/No
support 18B20
-40-110°C
support(-40~110°C)
Relay switch, current less than 10A
|
Support WeChat alarm notification
|
15 days cloud record, can be exported at any time
|
E-mail notification switch on switch off
|
Firmware version Remote firmware
|
Unit switch Celsius/Fahrenheit
|
Set temperature and hysteresis ‘
|
State: -O~ (Stop heating)
|
-
Automatic mode function description
-
The 1) first selects the heating mode / cooling mode;
-
sets the temperature and return difference. If the delay start is required, set the delay start time
-
If high and low temperature alarm is required, set high and low temperature alarm threshold
-
Heating mode description
When the detection temperature (current temperature) ^ sets temperature-return temperature, relay leads on and heating equipment starts working;
When the detection temperature (current temperature) ^ sets the temperature, the relay is disconnected and the heating equipment stops working;
For example: set temperature 30°C and return temperature 5°C;
When the temperature is 20°C s£ 25°C (30-5 = 25), the relay suction starts heating, when the temperature reaches 30°C > the set temperature is 30°C, the relay is disconnected and stops heating;
-
Refrigeration mode description
Detection temperature (current temperature) ^ set temperature + return temperature, relay leads on and refrigeration equipment starts working;
When the detection temperature (current temperature) ^ sets the temperature, the relay is disconnected and the refrigeration equipment stops working;
For example: set temperature 30°C and return temperature 5°C;
When the temperature is 36°C > 35°C (30 + 5 = 35), the relay suction starts refrigeration, when the temperature reaches 30°C s£ the set temperature is 30°C, the relay is disconnected and the cooling is stopped
-
Description of the time-delay startup function
How long is the delay (unit: seconds) after the first heating / cooling process will allow the next heating / cooling;
-
Temperature correction function
The system is working for a long time and may appear deviation. Through this function correction, the current temperature = measures the temperature + calibration value;
-
High-and low-temperature alarm function
buzzer on and off: on, the buzzer will sound after the alarm. After pressing the button, the buzzer stops sounding;
High temperature alarm: After the high temperature alarm is opened, after the current temperature is higher than the high temperature alarm temperature, the relay is disconnected;
Low temperature alarm: After opening the low temperature alarm, after the current temperature is below the low temperature alarm temperature, the relay is disconnected;
-
Emergency braking function (Emergency stop function)
After the emergency stop, the relay will be disconnected in whatever state; after the emergency stop is closed, the relay returns to normal state;
-
Whether the product can be run offline in automatic mode
In automatic mode, when the parameters are set, the product can run off the network offline, the parameter power loss is not lost.
-
The LAN data export function
A temperature data is transmitted on the LAN in 1 second. Click "Export", it is automatically exported to the EXCEL to analyze the temperature data
3.Manual mode description
5.operation note
All operation records can be stored in the background, and the + timer + button + APP + heating and cooling mode to query the relay operation status;
Type |
|
Time
|
| Execute
|
RESTART
|
2022-03-09 11:02:41
|
Relay OFF
|
HOT
|
2022-03-09 10:59:39
|
Relay ON
|
RESTART
|
2022-03-09 10:58:56
|
Relay OFF
|
RESTART
|
2022-03-09 10:16:50
|
Relay OFF
|
RESTART
|
2022-03-08 15:07:09
|
Relay OFF
|
COLD
|
2022-03-08 00:43:02
|
Relay OFF
|
HOT
|
2022-03-07 11:04:54
|
Relay ON
|
Alarm_OTP
|
2022-03-04 08:53:42
|
Relay OFF
|
HOT
|
2022-03-03 12:43:29
|
Relay ON
|
KEY
|
2022-03-03 11:55:13
|
E-stop Close
|
KEY
|
2022-03-03 11:55:09
|
E-stop Open
|
HOT
|
2022-03-03 11:34:03
|
Relay OFF
|
HOT
|
2022-03-02 14:40:02
|
Relay ON
|
RESTART
|
2022-03-02 14:00:04
|
Relay OFF
|
HOT
|
2022-03-02 13:49:19
|
Relay OFF
|
KEY
|
2022-03-02 13:49:06
|
E-stop Close
|
RESTART
|
2022-03-02 13:42:26
|
Relay OFF
|
RESTART
|
2022-03-02 13:34:57
|
Relay OFF
|
HOT
|
2022-03-0213:28:32
|
Relay ON
|
RESTART
|
2022-03-02 12:01:42
|
Relay OFF
|
|
Click load more
|
|
6.Cloud recording and upload frequency
6.1 Set upload rate
Temperature data can be stored in the background, the frequency of log upload can be set for 1 second / bar (one default 5 minutes); the data can be inquired for any time period at will and retain data within 15 days at the maximum period; the cloud data export function can be added to make the next analysis of the temperature data;
6.2 Cloud data export
You can choose to export data for any period of time within 15 days and save it locally for later data processing and analysis;
В ± i И Q 3:54
<- Control device
Start 2022-03-11 15:49
End 2022-03-11 15:54
Query
Data export
Note: cloud records can be kept for up to 15 days
Serial | Time | Temp(’C)
There is no data in this period
-
Key button function and indicator light status
7.1 Keybutton function
Short press:
On / off the relay in manual mode;
In automatic mode, turn the emergency stop function on / off
Note: under the buzzer alarm state, briefly press the key to cancel the buzzer alarm, and do not perform other actions;
Press for 5 seconds: switch the pairing mode Touch/AP, to let the product into the pairing state;
7.1 Description of the indicator lamp function
Blue indicator lamp: the network status indicator lamp
-
is not connected to the router: bright 1S out of 0.1S so reciprocating;
-
link router but not connected: flash once, flash once so backwards;
-
Touch pairing mode: flash 4 times and then wait 1S so reciprocating;
-
AP pairing mode: blue light continuous flash;
-
networking success: the blue indicator light is always on;
Green indicator lamp: touch on and emergency stop indicator lamp
Turn on the emergency stop, and the green indicator light will flash;
In manual mode, if the green indicator is on
Red indicator lamp: relay status indicator lamp;
-
Mail notification function:
-
How to bind a mailbox
Turn on the mail notification
|
|
|
|
|
|
|
firmware:V1.0.3
It's the latest
|
|
|
-
Open the APP into the device operation interface, the top left corner is the switch of the mail notification function; if the email notification is turned on, when the computer status sends the change will send the latest status and operation type of the computer in real time through the mailbox used to register the APP;
Operation types are divided into five types: 1. Equipment power 2. Key operation 3.
Timer operation 4.APP operation 5. Point operation operation; as shown in the figure below
-
Turn on the mailbox notification function for the device
-
opens sinilink APP, to find the added thermostat device and enter the operation interface;
There is a "WeChat | Mail Notification" switch in the top right corner of the 2., set to "open" to receive the email notification of the product;
The 3. mailbox notification type
High temperature and high high temperature alarm is lifted
Too low temperature and low temperature alarm is discharged
Sensor abnormal sensor abnormal abnormally
Start the heating and stop the heating
Start refrigeration and stop cooling
-
How to distribute the distribution
network
-
TouchTouch mode
1. Press the product button for more than 5 seconds to let the product into the Touch pairing state (the blue lights flash 4 times quickly and extinguish 1S so reciprocating)
2. The APP operation is as shown below:
|
-
AP model
Press the product button for more than 5 seconds to bring the product into the compatibility mode (AP mode) pairing state (the blue lights continuously flash
Sixth step
4:15 PM .’«■=: .Ill .Id fiW 48 }
<- Add Device
1. Press the matching button for a long time until the indicator flashes continuously (as shown below), when the device enters compatible matching mode
WLAN ®
Sa.ed
SinilinkProduct '* Connected
«I TP-LINK_2.4G_xinyi
Available network
Asfly
AsHobby
CAR-DVR-e912
Setting
Enter the phone setting interface and connect the WIFI network to Sini1inkProduct (password is 12345678)
2. Enter the mobile setup «iterface and connect the network to the SiniSnk Product network (password 12345678)
□ ia®
~~ -■■■ I
о «• 0 о «... •
1^
Go back to Sinilink APP and click “'Next*'
Next step
Seventh step
Click "Finish adding" and waitfor the mobile phone to connect successfully, and then automatically return to the app device interface
10.How to download a mobile APP
Scan Download АРР
Scan the code to download APP, foreign customers please download in Google market, search for 'sinilink' download